Resultados 1 - 20 de 32.501
Filtrar
1.
Clin Orthop Surg ; 16(2): 251-258, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562641

RESUMO

Background: The purpose of this study was to evaluate the clinical and radiological outcomes of high-flexion total knee arthroplasty (TKA) using Vega Knee System (B. Braun, Aesculap) at a long-term follow-up and to analyze the implant survivorship. Methods: We enrolled 165 patients (232 knees) with a minimum 7-year follow-up after TKA (VEGA Knee System). For clinical assessment, range of motion (ROM), Knee Injury and Osteoarthritis Outcome Score (KOOS), and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) were used. For radiologic assessment, hip-knee-ankle angle, component position, and the existence of radiolucent lines and loosening were used. Survival analysis was conducted using the Kaplan-Meier method. Results: The mean follow-up period was 9.8 years. The mean ROM increased from 124.4° to 131.4° at the final follow-up. The WOMAC score decreased from 38.5 to 17.4 at the final follow-up (p < 0.001). All 5 subscales of the KOOS improved at the final follow-up (all subscales, p < 0.001). Revision TKA was performed in 10 cases (4.3%), which included 9 cases of aseptic loosing and 1 case of periprostatic joint infection. Of the 9 aseptic loosening cases (3.9%), 8 cases (3.4%) were loosening of the femoral component and 1 case (0.4%) was loosening of the tibial component. When revision for any reason was considered an endpoint, the 10-year survivorship was 96.2% (95% confidence interval [CI], 93.9%-98.5%). On the other hand, when revision for aseptic loosening was considered the endpoint, the 10-year survivorship was 96.6% (95% CI, 94.4%-98.8%). Conclusions: The Vega Knee System provided good clinical results in the long-term follow-up period. Although the VEGA Knee System showed acceptable implant survivorship, loosening of the femoral component occurred in about 3.4% of the patients. For more accurate evaluation of the survivorship of high-flexion design TKA with a short posterior flange, it is necessary to conduct more long-term follow-up studies targeting diverse races, especially Asians who frequently perform high-flexion activities.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite , Humanos , Artroplastia do Joelho/métodos , Falha de Prótese , Resultado do Tratamento , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite/cirurgia , Reoperação , Amplitude de Movimento Articular , Desenho de Prótese , Seguimentos , Estudos Retrospectivos
2.
Acta Orthop ; 95: 157-165, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38597226

RESUMO

BACKGROUND AND PURPOSE:  Different marker-selection methods are applied to represent implant and tibial segments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations ("consistent-marker method") is used or all available markers at each follow-up ("all-marker method"). The aim of this secondary analysis was to compare marker-selection methods on individual and group level TKA migration results. METHODS:  Data from a randomized RSA study with 72 patients was included. Tibial baseplate migration was evaluated at 3 months, 1, 2, and 5 years postoperatively with both marker-selection methods. Additionally, migration was calculated using 5 fictive points, either plotted based on the consistent set of markers or all available markers. RESULTS:  Migration could be calculated with both marker-selection methods for 248 examinations. The same prosthesis and bone markers (n = 136), different prosthesis markers (n = 71), different bone markers (n = 21), or different prosthesis and bone markers (n = 20) were used. The mean difference in maximum total point motion (MTPM) between all examinations was 0.02 mm, 95% confidence interval -0.26 to 0.31 mm. 5 implants were classified as continuously migrating with the consistent-marker method versus 6 implants (same 5 plus one additional implant) with the all-marker method. Using fictive points, fewer implants were classified as continuously migrating in both marker-selection methods. Differences between TKA groups in mean MTPM were comparable with both marker-selection methods, also when fictive points were used. CONCLUSION:  Estimated group differences in mean MTPM were similar between marker-selection methods, but individual migration results differed. The latter has implications when classifying implants for estimated risk of future loosening.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Seguimentos , Análise Radioestereométrica , Falha de Prótese , Desenho de Prótese , Osteoartrite do Joelho/cirurgia
3.
BMC Musculoskelet Disord ; 25(1): 259, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566097

RESUMO

BACKGROUND: Modular neck femoral stems are advantageous because they can accurately restore the ideal hip geometry using various options in terms of offset, length, and version. However, there are concerns regarding junctional problems. Despite several reports on such issues, there is a lack of study on mid- to long-term results of these stems. The current study evaluated the mid-term results of patients who underwent primary total hip arthroplasty using a titanium-titanium (Ti-Ti) modular neck femoral stem. METHODS: In total, data on 47 hips (42 patients) that could be followed-up for ≥ 5 years after primary total hip arthroplasty using the Ti-Ti modular neck femoral stem from 2011 to 2015 were reviewed. There were 22 male and 20 female patients, and their mean age was 56.3 (range: 31-76) years. The mean follow-up period was 8 (range: 5-12) years. Functional and radiological outcomes, complications, and reoperations were investigated. In addition, we conducted a comparative analysis of the outcomes between those who underwent surgery using the Ti-Ti modular neck femoral stem and 41 hips (35 patients, 19 males and 16 females) that underwent primary total hip arthroplasty using nonmodular femoral stems as a control. RESULTS: In all Ti-Ti cases, the mean Harris Hip Scores were 50.6 (range: 6-59) preoperatively and 92.7 (range: 78-99) at the last follow-up (P < 0.001). Regarding the neck component's modularity, straight neck components were used in all Ti-Ti cases, and an anteverted or a retroverted neck was not used in any case. Stem revision was performed in one hip due to aseptic loosening. One hip underwent open reduction and internal fixation due to periprosthetic fracture without stem loosening. There were no cases of osteolysis and periprosthetic joint infection and clinically detectable junctional problems. The stem survival rate, with any stem revision as the endpoint, at 12 years was 96.6%. No significant difference was observed in the functional and radiological outcomes beween the Ti-Ti and nonmodular groups. CONCLUSIONS: The Ti-Ti modular neck femoral stem had comparable results with broadly used nonmodular femoral stems; hence, it can be a reliable option in primary total hip arthroplasty. However, in terms of the modularity itself of the modular neck femoral stem, whether the modular neck femoral stem is useful in uncomplicated primary total hip arthroplasty is unclear.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Titânio , Desenho de Prótese , Estudos Retrospectivos , Reoperação , Seguimentos , Falha de Prótese
4.
Echocardiography ; 41(4): e15804, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38578295

RESUMO

A 60-year-old man presented with breathlessness. Nearly four decades previously, he had required three operations for Staphylococcus aureus infective endocarditis of the tricuspid valve and had received a bioprosthetic valve. He had critical tricuspid bioprosthesis stenosis which was treated successfully by valve-in-valve transcatheter tricuspid valve replacement using a balloon-expandable transcatheter heart valve. One year after intervention, the patient is well with no tricuspid valve stenosis or regurgitation.


Assuntos
Bioprótese , Endocardite Bacteriana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Estenose da Valva Tricúspide , Masculino , Humanos , Pessoa de Meia-Idade , Adulto , Bioprótese/efeitos adversos , Constrição Patológica , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/cirurgia , Resultado do Tratamento , Desenho de Prótese , Falha de Prótese
5.
BMC Musculoskelet Disord ; 25(1): 277, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600536

RESUMO

INTRODUCTION: The number of primary and revision Total Knee Arthroplasty (TKA) cases are expected to increase in future. There are various advantages and disadvantage to employing either of the two main types of stem fixation methods - cemented or hybrid technique. This review aimed to study the most optimal fixation method for revision TKAs by comparing radiological outcomes and re-revision rates. METHODS: A systematic review and meta-analysis was performed using PubMed and Cochrane Library from 2010 to identify studies explicitly comparing outcomes between cemented against hybrid fixation revision TKA techniques, with a minimum follow up of at least 24 months. A total of 8 studies was included in this review. Egger's test and visual inspection of the funnel plot did not reveal publication bias. RESULTS: There was no statistically significant difference in radiological failure and loosening (OR 0.79, CI 0.37-1.66, I2 = 29%, p = 0.22), all causes of re-revision (OR 1.03, CI 0.73-1.44, I2 = 0%, p = 0.56) and aseptic revision (OR 0.74, CI 0.27-2.02, I2 = 0%, p = 0.41) between cemented and hybrid techniques. Functional and pain outcomes compared between the two fixation techniques were largely similar across the studies included in this meta-analysis. CONCLUSION: Despite a trend favouring hybrid stems in revision TKA, current evidence revealed that radiological outcomes and re-revision rates are largely similar between cemented and hybrid fixation techniques.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Cimentos Ósseos/uso terapêutico , Exame Físico , Desenho de Prótese , Falha de Prótese , Reoperação/métodos , Resultado do Tratamento
6.
Arterioscler Thromb Vasc Biol ; 44(5): 1065-1085, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38572650

RESUMO

Blood vessels are subjected to complex biomechanical loads, primarily from pressure-driven blood flow. Abnormal loading associated with vascular grafts, arising from altered hemodynamics or wall mechanics, can cause acute and progressive vascular failure and end-organ dysfunction. Perturbations to mechanobiological stimuli experienced by vascular cells contribute to remodeling of the vascular wall via activation of mechanosensitive signaling pathways and subsequent changes in gene expression and associated turnover of cells and extracellular matrix. In this review, we outline experimental and computational tools used to quantify metrics of biomechanical loading in vascular grafts and highlight those that show potential in predicting graft failure for diverse disease contexts. We include metrics derived from both fluid and solid mechanics that drive feedback loops between mechanobiological processes and changes in the biomechanical state that govern the natural history of vascular grafts. As illustrative examples, we consider application-specific coronary artery bypass grafts, peripheral vascular grafts, and tissue-engineered vascular grafts for congenital heart surgery as each of these involves unique circulatory environments, loading magnitudes, and graft materials.


Assuntos
Prótese Vascular , Hemodinâmica , Humanos , Animais , Modelos Cardiovasculares , Falha de Prótese , Estresse Mecânico , Fenômenos Biomecânicos , Mecanotransdução Celular , Implante de Prótese Vascular/efeitos adversos , Desenho de Prótese , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/etiologia , Remodelação Vascular
7.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 455-460, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632066

RESUMO

Objective: To explore the short-term effectiveness of hip revision surgery guided by artificial intelligence preoperative planning (AIHIP) system. Methods: The clinical data of 22 patients (23 hips) who were admitted between June 2019 and March 2023 and met the selection criteria were retrospectively analyzed. There were 12 males and 10 females with an average age of 69.7 years (range, 44-90 years). There were 19 hips in the first revision, 3 hips in the second revision, and 1 hip in the third revision. The causes of revision included 12 hips with prosthesis loosening, 4 hips with acetabular cup loosening, 3 hips with osteolysis, 2 hips with acetabular dislocation, 1 hip with postoperative infection, and 1 hip with prosthesis wear. There were 6 hips in stage ⅡA, 9 hips in stage ⅡB, 4 hips in stage ⅡC, 3 hips in stage ⅢA, and 1 hip in stage ⅢB according to Paprosky staging of acetabular bone defect. The replacement of prosthesis type, operation time, hospitalization stay, ground active condition, and postoperative infection, fracture, prosthesis loosening, and other adverse events were recorded. The function of the affected limb was evaluated by Harris score before operation, at 1 week and 6 months after operation, and the range of motion of the hip joint was compared before operation and at 6 months after operation. Results: The operation time was 85-510 minutes, with an average of 241.8 minutes; the hospitalization stay was 7-35 days, with an average of 15.2 days; the time of disassociation from the walker was 2-108 days, with an average of 42.2 days. All the 22 patients were followed up 8-53 months (mean, 21.7 months). No adverse events such as prosthesis loosening or infection occurred in the rest of the patients, except for postoperative hematoma of the thigh in 1 patient and dislocation of the hip in 1 hip. The matching degree of acetabular cup was completely matched in 22 hips and mismatched in 1 hip (+2), the matching rate was 95.65%. The matching degree of femoral stem was completely matched in 22 hips and generally matched in 1 hip (-1), and the matching rate was 100%. The Harris scores were 55.3±9.8 and 89.6±7.2 at 1 week and 6 months after operation, respectively, which significantly improved when compared with before operation (33.0±8.6, P<0.05), and further improved at 6 months after operation than at 1 week after operation ( P<0.05). The function of hip joint was evaluated by Harris score at 6 months after operation, and 21 hips were good and 2 hips were moderate, which could meet the needs of daily life. The range of motion of hip joint was (111.09±10.11)° at 6 months after operation, which was significantly different from (79.13±18.50)° before operation ( t=-7.269, P<0.001). Conclusion: AIHIP system can improve the accuracy of revision surgery, reduce the difficulty of surgery, and achieve good postoperative recovery and satisfactory short-term effectiveness.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Masculino , Feminino , Humanos , Idoso , Falha de Prótese , Reoperação , Estudos Retrospectivos , Inteligência Artificial , Seguimentos , Resultado do Tratamento , Articulação do Quadril/cirurgia , Acetábulo/cirurgia , Complicações Pós-Operatórias , Luxações Articulares/cirurgia
8.
Acta Ortop Mex ; 38(1): 15-21, 2024.
Artigo em Espanhol | MEDLINE | ID: mdl-38657147

RESUMO

INTRODUCTION: reconstruction of large bone defects using modular knee arthroplasty (MKA) presents a significant challenge in terms of functionality. The objective of the present work was to identify the different prognostic factors associated with failure of MKA in cancer patients. MATERIAL AND METHODS: a retrospective cohort study was conducted, including patients with a diagnosis of musculoskeletal tumor in the distal femur or proximal tibia, who underwent MKA between January 1, 2010, and December 31, 2021. RESULTS: 49 patients were included, of which 25 (51.02%) were women and 24 (48.98%) men, with a mean age of 29.57 years. Of these, 14 (28.57%) patients experienced some type of MKA failure. The most frequent complication that led to failure was periprosthetic infection, observed in seven (14.29%) patients. Variables associated with MKA failure included biopsies performed outside our hospital (HR 3.2, 95% CI 1.4-6.4, p = 0.02), the length of the long axis of the tumor (HR 2.1, 95% CI 1.2-4.6, p = 0.01) and a prolonged surgical time (HR 3.37, 95% CI 1.1-8.6, p = 0.04). CONCLUSION: the most significant prognostic factors associated with MKA failure in our cohort were tumor size, prolonged surgical time, and performance of the diagnostic biopsy in a center not specialized in the management of this type of patient. These findings highlight the importance of considering these variables to improve outcomes in patients undergoing MKA.


INTRODUCCIÓN: la reconstrucción de grandes defectos óseos mediante artroplastía modular de rodilla (AMR) representa un desafío significativo en términos de funcionalidad. El objetivo del presente trabajo fue identificar los diferentes factores pronósticos asociados al fracaso de la AMR en pacientes oncológicos. MATERIAL Y MÉTODOS: se realizó un estudio de cohorte retrospectiva, incluyendo pacientes con diagnóstico de tumor musculoesquelético en el fémur distal o la tibia proximal, que fueron sometidos a AMR entre el 1 de Enero de 2010 y el 31 de Diciembre de 2021. RESULTADOS: se incluyeron 49 pacientes, de los cuales 25 (51.02%) eran mujeres y 24 (48.98%) hombres, con una edad media de 29.57 años. De éstos, 14 (28.57%) pacientes experimentaron algún tipo de fracaso de la AMR. La complicación más frecuente que condicionó el fracaso fue la infección periprotésica, observada en siete (14.29%) pacientes. Las variables asociadas con el fracaso de las AMR incluyeron biopsias realizadas fuera de nuestro hospital (HR 3.2, IC95% 1.4-6.4, p = 0.02), longitud del eje mayor del tumor (HR 2.1, IC95% 1.2-4.6, p = 0.01) y tiempo quirúrgico prolongado (HR 3.37, IC95% 1.1-8.6, p = 0.04). CONCLUSIÓN: los factores pronósticos asociados al fracaso de las AMR en nuestra cohorte fueron el tamaño del tumor, un tiempo quirúrgico prolongado y la realización de la biopsia diagnóstica en un centro no especializado en el manejo de este tipo de pacientes. Estos hallazgos resaltan la importancia de considerar estas variables en pacientes sometidos a AMR.


Assuntos
Artroplastia do Joelho , Humanos , Masculino , Feminino , Estudos Retrospectivos , Artroplastia do Joelho/métodos , Adulto , Prognóstico , Pessoa de Meia-Idade , Neoplasias Ósseas/cirurgia , Adulto Jovem , Infecções Relacionadas à Prótese/etiologia , Duração da Cirurgia , Falha de Prótese , Tíbia/cirurgia , Adolescente , Prótese do Joelho , Falha de Tratamento
9.
J Arthroplasty ; 39(4): 991-996, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38661490

RESUMO

BACKGROUND: We aimed to compare the clinical outcomes of different head sizes (28-, 32-, and 36- millimeter) in primary total hip arthroplasty (THA) at mean 6 years follow-up (range, 1 to 17.5 years). METHODS: This was a retrospective consecutive study of primary THA at our institution (2003 to 2019). Demographic and surgical data were collected. The primary outcome measures were all-cause revision, revision for dislocation, and all-cause revision excluding dislocation. Continuous descriptive statistics used means, median values, ranges, and 95% confidence intervals, where appropriate. Kaplan-Meier survival curves were used to estimate time to revision. Cox proportional hazard regression analyses were used to compare revision rates between the femoral head size groups. Adjustments were made for age at surgery, sex, primary diagnosis, American Society of Anesthesiologists score, articulation type, and fixation methods. There were 10,104 primary THAs included; median age was 69 years (range, 13 to 101) with 61.5% women. A posterior approach was performed in 71.6%. There were 3,295 hips with 28-mm heads (32.6%), 4,858 (48.1%) with 32-mm heads, and 1,951 (19.3%) with 36-mm heads. RESULTS: Overall rate of revision was 1.7% with the lowest rate recorded for the 36-mm group (2.7 versus 1.3 versus 1.1%). Cox regression analyses showed a decreased risk of all-cause revision for 32 and 36-mm head sizes as compared to 28-mm; this was statistically significant for the 32-mm group (P = .01). Risk of revision for dislocation was significantly reduced in both 32-mm (P = .03) and 36-mm (P = .03) head sizes. Analysis of all cause revision excluding dislocation showed no significant differences between head sizes. CONCLUSIONS: We found a significantly reduced risk of revision for all causes, but particularly revision for dislocation with larger head sizes. Concerns regarding increased risk of early revision for aseptic loosening, polyethylene wear, or taper corrosion with larger heads appear to be unfounded in this cohort of 10,104 patients with up to 17 years follow-up.


Assuntos
Artroplastia de Quadril , Cabeça do Fêmur , Prótese de Quadril , Falha de Prótese , Reoperação , Humanos , Artroplastia de Quadril/instrumentação , Feminino , Masculino , Reoperação/estatística & dados numéricos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Adulto , Cabeça do Fêmur/cirurgia , Idoso de 80 Anos ou mais , Adolescente , Desenho de Prótese , Adulto Jovem , Seguimentos , Fatores de Risco
10.
Med Eng Phys ; 126: 104159, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621833

RESUMO

Generation of polyethylene wear debris and peri­prosthetic bone resorption have been identified as potential causes of acetabular component loosening in Total Hip Arthroplasty. This study was aimed at optimization of a functionally graded porous acetabular component to minimize peri­prosthetic bone resorption and polyethylene liner wear. Porosity levels (porosity values at acetabular rim, and dome) and functional gradation exponents (radial and polar) were considered as the design parameters. The relationship between porosity and elastic properties were obtained from numerical homogenization. The multi-objective optimization was carried out using a non-dominated sorting genetic algorithm integrated with finite element analysis of the hemipelvises subject to various loading conditions of common daily activities. The optimal functionally graded porous designs (OFGPs -1, -2, -3, -4, -5) exhibited less strain-shielding in cancellous bone compared to solid metal-backing. Maximum bone-implant interfacial micromotions (63-68 µm) for OFGPs were found to be close to that of solid metal-backing (66 µm), which might facilitate bone ingrowth. However, OFGPs exhibited an increase in volumetric wear (3-10 %) compared to solid metal-backing. The objective functions were found to be more sensitive to changes in polar gradation exponent than radial gradation exponent, based on the Sobol' method. Considering the common failure mechanisms, OFGP-1, having highly porous acetabular rim and less porous dome, appears to be a better alternative to the solid metal-backing.


Assuntos
Artroplastia de Quadril , Reabsorção Óssea , Prótese de Quadril , Humanos , Porosidade , Acetábulo/cirurgia , Metais , Polietileno , Reabsorção Óssea/cirurgia , Algoritmos , Desenho de Prótese , Falha de Prótese
11.
Med Eng Phys ; 126: 104142, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621844

RESUMO

Total hip arthroplasty (THA) surgeries among young patients are on the increase, so it is crucial to predict the lifespan of hip implants correctly and produce solutions to improve longevity. Current implants are designed and tested against walking conditions to predict the wear rates. However, it would be reasonable to include the additional effects of other daily life activities on wear rates to predict convergent results to clinical outputs. In this study, 14 participants are recruited to perform stair ascending (AS), descending (DS), and walking activities to obtain kinematic and kinetic data for each cycle using marker based Qualisys motion capture (MOCAP) system. AnyBody Modeling System using the Calibrated Anatomical System Technique (CAST) full body marker set are performed Multibody simulations. The 3D generic musculoskeletal model used in this study is a marker-based full-body motion capture model (AMMR,2.3.1 MoCapModel) consisting of the upper extremity and the Twente Lower Extremity Model (TLEM2). The dynamic wear prediction model detailing the intermittent and overall wear rates for CoCr-on-XLPE bearing couple is developed to investigate the wear mechanism under 3D loading for AS, DS, and walking activities over 5 million cycles (Mc) by using finite element modelling technique. The volumetric wear rates of XLPE liner under AS, DS, and walking activities over 5-Mc are predicted as 27.43, 23.22, and 18.84 mm3/Mc respectively. Additionally, the wear rate was predicted by combining stair activities and gait cycles based on the walk-to-stair ratio. By adding the effect of stair activities, the volumetric wear rate of XLPE is predicted as 22.02 mm3/Mc which is equivalent to 19.41% of walking. In conclusion, in this study, the effect of including other daily life activities is demonstrated and evidence is provided by matching them to the clinical data as opposed to simulator test results of implants under ISO 14242 boundary conditions.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Longevidade , Marcha , Fenômenos Biomecânicos , Falha de Prótese , Desenho de Prótese
12.
BMC Musculoskelet Disord ; 25(1): 312, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649874

RESUMO

BACKGROUND: Hip offset, version, and length are interdependent femoral variables which determine stability and leg length. Balancing these competing variables remains a core challenge in hip arthroplasty. The potential benefits of modular femoral stems have been overshadowed by higher rates of failure. The objective of this study was to assess the survivorship of a unique dual-modular femoral stem at an average 15-year follow-up period. METHODS: The records of all patients with osteoarthritis who underwent primary total hip arthroplasty with this device between 2004-2009 were reviewed. There were no exclusions for BMI or other factors. We examined the data with Kaplan-Meier survival analysis. The primary endpoint for survival was mechanical failure of the modular neck-body junction. RESULTS: The survivorship of this device in 172 subjects was 100% with none experiencing mechanical failure of the modular junction at an average of 15 years. 60 patients died of causes unrelated to their THA and 9 patients were lost to follow-up. There were three early (≤ 12 months) dislocations (1.7%), and seven total dislocations (4.1%). 16 patients underwent reoperations during the follow-up period, none for any complication of the modular junction. Radiographic results showed well-fixed femoral stems in all cases. There were no leg length discrepancies of greater than 10 mm, and 85% were within 5 mm. CONCLUSION: There were no mechanical failures of the modular junction in any of the subjects over the average 15-year period, demonstrating that this dual-modular design is not associated with increased failure rates. We achieved a 1.7% early dislocation rate and a 4.1% total dislocation rate without any clinically significant leg length discrepancies.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Seguimentos , Osteoartrite do Quadril/cirurgia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estimativa de Kaplan-Meier , Reoperação/estatística & dados numéricos , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fatores de Tempo
13.
Acta Orthop Traumatol Turc ; 58(1): 68-72, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38525513

RESUMO

Oxidized zirconium (OxiniumTM) prostheses, made up of a metallic alloy of zirconium with a ceramic surface formed by oxidizing the outer layer, were developed as an alternative bearing surface to reduce polyethylene wear and decrease failure of total knee arthroplasty (TKA). We report a unique catastrophic failure of an Oxinium TKA with consequent accelerated wear and severe metallosis. Intraoperatively, we observed extensive wear grooving of the femoral component with exposure of the underlying silver layers and the complete wear of polyethylene on the medial side. Metallic debris had a peculiar arthrogram appearance, noted within the cut surface of the femur and tibia, indicative of the osteolysis that occurred, leading up to the failure of the implants. The histopathologic examination revealed a collection of macrophages with foreign-body reactions and black-pigmented metal-induced wear particles. Oxinium has clear benefits regarding superior wear properties; however, surgeons need to be aware that there is a risk of exposure to the underlying layers that may precede accelerated wear, deformation, and metallosis. Uncovering the deeper layers could result in the appearance of an arthrogram on plain radiographs. Early identification of polyethylene wear and prompt revision is crucial to avoid the rapid progression of subsequent metallosis and catastrophic implant failure, specifically when using oxidized zirconium components for TKA. To the best of our knowledge, this is the first report presenting a detailed histologic analysis to provide insight into the mechanisms of the failed Oxinium components.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Zircônio/efeitos adversos , Desenho de Prótese , Prótese do Joelho/efeitos adversos , Polietileno/efeitos adversos , Falha de Prótese
14.
Medicina (Kaunas) ; 60(3)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38541184

RESUMO

Background and objectives: wear and corrosion can lead to the gross failure of the Morse taper junction with the consequent fracture of the true neck of the prosthetic stem in hip arthroplasty. Materials and Methods: 58-year-old male patient, with a BMI of 38 kg/m2. Because of avascular necrosis, in 2007, a metal-on-metal total hip arthroplasty was implanted in him, with a TMZF stem and a Co-Cr head. In December 2020, he complained of acute left hip pain associated with the deterioration of his left leg and total functional impairment, preceded by the crunching of the hip. X-rays and CT scan showed a fracture of the prosthetic neck that necessitated prosthetic revision surgery. A Scanning Electron Microscope (SEM) analysis of the retrieved prosthetic components was conducted. Results: Macroscopically, the trunnion showed a typical bird beak appearance, due to a massive material loss of about half of its volume. The gross material loss apparently due to abrasion extended beyond the trunnion to the point of failure on the true neck about half a centimeter distal from the taper. SEM analysis demonstrated fatigue rupture modes, and the crack began close to the neck's surface. On the lateral surface, several scratches were found, suggesting an intense wear that could be due to abrasion. Conclusions: The analysis we conducted on the explanted THA showed a ductile rupture, began close to the upper surface of the prosthetic neck where the presence of many scratches had concentrated stresses and led to a fatigue fracture.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Microscopia Eletrônica de Varredura , Falha de Prótese , Desenho de Prótese
15.
Am J Cardiol ; 217: 25-28, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38432337

RESUMO

What is the efficacy and safety of transcatheter tricuspid valve-in-valve implantation for patients with inoperable tricuspid surgical prosthesis dysfunction? Thirty-day mortality after greatly effective transcatheter treatment is 2 times less than the estimated surgical risk.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Humanos , Falha de Prótese , Valva Tricúspide/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco , Desenho de Prótese , Insuficiência Cardíaca/cirurgia
16.
J Am Heart Assoc ; 13(7): e033176, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38533939

RESUMO

BACKGROUND: It remains controversial whether prosthesis-patient mismatch (PPM) impacts long-term outcomes after surgical aortic valve replacement. We aimed to evaluate the association of PPM with mortality, rehospitalizations, and aortic valve reinterventions. METHODS AND RESULTS: We performed a systematic review with meta-analysis of reconstructed time-to-event data of studies published by March 2023 (according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses). Sixty-five studies met our eligibility criteria and included 122 989 patients (any PPM: 68 332 patients, 55.6%). At 25 years of follow-up, the survival rates were 11.8% and 20.6% in patients with and without any PPM, respectively (hazard ratio [HR], 1.16 [95% CI, 1.13-1.18], P<0.001). At 20 years of follow-up, the survival rates were 19.5%, 12.1%, and 8.8% in patients with no, moderate, and severe PPM, respectively (moderate versus no PPM: HR, 1.09 [95% CI, 1.06-1.11], P<0.001; severe versus no PPM: HR, 1.29 [95% CI, 1.24-1.35], P<0.001). PPM was associated with higher risk of cardiac death, heart failure-related hospitalizations, and aortic valve reinterventions over time (P<0.001). Statistically significant associations between PPM and worse survival were observed regardless of valve type (bioprosthetic versus mechanical valves), contemporary PPM definitions unadjusted and adjusted for body mass index, and PPM quantification method (in vitro, in vivo, Doppler echocardiography). Our meta-regression analysis revealed that populations with more women tend to have higher HRs for all-cause death associated with PPM. CONCLUSIONS: The results of the present study suggest that any degree of PPM is associated with poorer long-term outcomes following surgical aortic valve replacement and provide support for implementation of preventive strategies to avoid PPM after surgical aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Falha de Prótese , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Fatores de Risco , Desenho de Prótese
17.
J Mech Behav Biomed Mater ; 153: 106474, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38447273

RESUMO

Total Hip Arthroplasty has been a revolutionary technique in restoring mobility to patients with damaged hip joints. The introduction of modular components of the hip prosthesis allowed for bespoke solutions based on the requirements of the patient. The femoral stem is designed with a conical trunnion to allow for assembly of different femoral head sizes based on surgical requirements. The femoral head diameters for a metal-on-polyethylene hip prosthesis have typically ranged between 22 mm and 36 mm and are typically manufactured using Cobalt-Chromium alloy. A smaller femoral head diameter is associated with lower wear of the polyethylene, however, there is a higher risk of dislocation. In this study, a finite element model of a standard commercial hip arthroplasty prosthesis was modelled with femoral head diameters ranging from 22 mm to 36 mm to investigate the wear evolution and material loss at both contacting surfaces (acetabular cup and femoral stem trunnion). The finite element model, coupled with a validated in-house wear algorithm modelled a human walking for 10 million steps. The results have shown that as the femoral head size increased, the amount of wear on all contacting surfaces increased. As the femoral head diameter increased from 22 mm to 36 mm, the highly cross-linked polyethylene (XLPE) volumetric wear increased by 61% from 98.6 mm3 to 159.5 mm3 while the femoral head taper surface volumetric wear increased by 21% from 4.18 mm3 to 4.95 mm3. This study has provided an insight into the amount of increased wear as the femoral head size increased which can highlight the life span of these prostheses in the human body.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Cabeça do Fêmur , Análise de Elementos Finitos , Desenho de Prótese , Falha de Prótese , Polietileno , Ligas de Cromo
18.
Int Orthop ; 48(5): 1241-1247, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38499712

RESUMO

PURPOSE: The aims of this study were to evaluate the survivorships of a new generation cementless DMC with tripod additional fixation in revision total hip arthroplasty and complications at a minimum five year follow-up. METHODS: One hundred and fifteen revisions (THA) treated with tripod DMC performed between 2009 and 2015 were included in this retrospective study. Acetabular defects were classified as Paprosky 1 (n = 38, 33%), 2 (n = 75, 65%) or 3 (n = 2, 2%). Unipolar or bipolar revision was performed for the following indications: aseptic acetabular loosening (63%), infection (14%), aseptic bipolar loosening (11%), instability (4%), aseptic femoral loosening (3%), ALVAL (3%) and iliopsoas impingement (2%). Mean follow-up was 9.4 years ± two (range, 5 to 14). RESULTS: At the final follow-up, a single episode of dislocation occurred within three months after the procedure (0.8%) with no revision. Three cases of aseptic loosening were diagnosed (2.6%). Four infections (3.5%) required reoperation: three required a two stage bipolar revision; one was treated by DAIR procedure. At the latest follow-up, the survivorship of the acetabular cup for aseptic loosening was 98% [95% CI (91.2-99.4)] and for any reasons was 94.4% [95% CI (90.1%-98.9%)]; the mean HHS improved from 60 points (range, 18-94 points) to 83 points (range, 37-100 points) (p < .001). CONCLUSION: This study reports a low complication rate in favour of the use of a tripod DMC in revision THA with a satisfactory survivorship at a ten year follow-up.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Falha de Prótese , Acetábulo/cirurgia , Reoperação , Desenho de Prótese , Seguimentos
19.
Int J Artif Organs ; 47(4): 299-302, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38515386

RESUMO

This article describes three cases in which a dislocated hip prosthesis was reduced by a new reduction technique - that we previously described - using traction table. The dissociation of a prosthesis is a rare but serious complication of closed reduction manoeuvre. The new reduction manoeuvre using a traction table may be a good option to avoid dissociation of the prosthesis during closed reduction for treatment of dislocation after total hip arthroplasty.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Tração , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Idoso , Feminino , Masculino , Luxação do Quadril/cirurgia , Luxação do Quadril/etiologia , Luxação do Quadril/diagnóstico por imagem , Falha de Prótese , Pessoa de Meia-Idade , Resultado do Tratamento
20.
Proc Inst Mech Eng H ; 238(4): 438-443, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38439747

RESUMO

With low wear rates shown by contemporary bearing materials of total hip prostheses, the standard deviation of wear rate is relatively high. Therefore, large sample sizes are needed for an adequate power of test. Because wear tests take a long time, it is practical to test several samples simultaneously. A new high-capacity, multidirectional wear test device, called the SuperCTPOD-200, was introduced. A 3 million-cycle wear test with an unprecedented sample size of 200 was performed for VEXLPE. The duration of the test was 6 weeks. The wear factor was normally distributed with a mean ± SD of 1.64 × 10-7 mm3/Nm ± 0.22 × 10-7 mm3/Nm (n = 200). The observation that SD was 13.1% of the mean can be useful in power analyses of future tests with other highly cross-linked polyethylenes. Burnishing was the most typical feature on the worn pins, which was in agreement with clinical findings on retrieved acetabular liners. The present study emphasizes statistics that often plays a minor role only in wear studies.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Teste de Materiais , Óxido de Alumínio , Polietilenos , Falha de Prótese